Enerzip 800 kW / 1000 kVA Diesel Generators Powered by Perkins Engines
| Price: | Үнэ тохиролцоно / Тохиргооноос хамаарна |
Enerzip 800 kW / 1000 kVA Diesel Generators Powered by Perkins Engines are designed for industrial prime power, standby power and emergency backup power applications. This generator model is suitable for factories, mining sites, oil and gas facilities, data centers, hospitals, commercial buildings, construction projects, manufacturing plants and other applications requiring reliable three-phase diesel power.
This Enerzip diesel generator is powered by a Perkins 4008-30TAG2 diesel engine and matched with a high-efficiency brushless alternator, intelligent generator controller, heavy-duty steel base frame, industrial exhaust silencer, radiator cooling system and standard protection devices. The generator can be supplied as an open type, silent type, containerized type or customized generator solution according to project requirements.
The generator is suitable for both prime power and standby power applications. It can be used as a single generator set or integrated with ATS panels, synchronizing panels, output cabinets, combining cabinets, distribution cabinets and remote monitoring systems for larger industrial power systems.
Power Rating and Operating Conditions
The prime power rating is designed for variable load applications where the generator may operate for an unlimited number of annual operating hours in accordance with ISO 8528-1. The standby power rating is designed for emergency power supply in variable load applications in accordance with ISO 8528-1. Overload is not allowed under standby power operation.
The nominal power rating is based on standard reference conditions, including 25°C air inlet temperature, 100 kPa barometric pressure and 30% relative humidity. For high ambient temperature, high altitude or special site conditions, generator output and cooling configuration should be confirmed according to actual project requirements.
Main Generator Specifications
| Prime Power | 800 kW / 1000 kVA |
| Standby Power | 880 kW / 1100 kVA |
| Frequency | 50 Hz |
| Phase | 3 Phase |
| Power Factor | 0.8 |
| Speed | 1500 rpm |
| Standard Voltage | 400/230V |
| Available Voltage | 380/220V, 415/240V |
| Fuel Type | Diesel |
| Cooling System | Water-cooled |
| Application | Prime Power and Standby Power |
General Installation Data
| Type | Open Type | Silent Type |
| Dimension L x W x H | 4630 x 2135 x 2250 mm | 5812 x 2290 x 2525 mm |
| Weight | 8243 kg | 11361 kg |
| Fuel Tank | Based on configuration | 1000 L |
| Sound Pressure Level | Based on installation | TBA according to canopy design |
Weights, dimensions and fuel tank capacity are based on standard generator configurations. Final data may vary according to alternator brand, canopy structure, fuel tank design, control system, voltage configuration and other project requirements.
Engine Specifications
| Engine Brand | Perkins |
| Engine Model | 4008-30TAG2 |
| Engine Type | 4-stroke diesel engine |
| Displacement | 30.561 L |
| Cylinder Arrangement | 8L |
| Bore x Stroke | 160 x 190 mm |
| Compression Ratio | 13:1 |
| Aspiration | Turbocharged and intercooled |
| Governor | Electronic governor |
| Engine Speed | 1500 rpm |
| Fuel | Diesel |
Fuel Consumption Data
| Load Condition | Fuel Consumption |
| 100% Standby Power | 234 L/h |
| 100% Prime Power | 213 L/h |
| 75% Prime Power | 160 L/h |
| 50% Prime Power | 108 L/h |
Engine System Data
| Exhaust Stack Gas Temperature Max. | 473°C |
| Exhaust Gas Flow Rate Max. | 203 m³/min |
| Maximum Allowable Exhaust Back Pressure | 7.5 kPa |
| Maximum Restriction at Lift Pump | 3 Bar |
| Maximum Fuel Flow | 660 L/h |
| Radiator Air Flow | 26.2 m³/s |
| Total Oil Capacity | 153 L |
| Total Coolant Capacity | 160 L |
| Starter Motor Rated Voltage | DC24V |
| Start Battery | 2 x 120Ah |
| Battery Charging Alternator | DC24V / 55A |
| Air Filter | Dry type |
| Maximum Combustion Air Intake Restriction | 5.0 kPa |
| Combustion Air Inlet Flow Rate | 84 m³/min |
| Maximum Allowable Combustion Air Inlet Temperature | 50°C |
Alternator Specifications
The generator is matched with a high-efficiency brushless alternator selected according to the required voltage, frequency, site load condition and project configuration. Different alternator brands and excitation systems can be supplied according to customer requirements.
| Alternator Type | Brushless |
| Excitation Type | Self-excited |
| Insulation and Temperature Rise | Class H/H |
| Phase | Three phase |
| Winding Leads | 6 |
| Standard Winding Connection | Star |
| Winding Pitch | Two thirds |
| Number of Bearings | Single bearing |
| Coupling System | Flexible disc coupling |
| Maximum Overspeed | 2250 rpm |
| Coating Type | Vacuum impregnation |
| Protection Class | IP23 |
Control System
The Enerzip 800 kW / 1000 kVA diesel generator can be equipped with an intelligent generator controller for prime power, standby power and automatic mains failure applications. The controller supports generator monitoring, engine protection, alternator protection and operating history management.
- Manual start and remote start operation
- Auto mains failure function for standby power applications
- Generator voltage, current, frequency, power factor and power monitoring
- Engine protection and alternator protection functions
- Emergency stop function
- Event log, running hours record and maintenance warning
- LCD display for easy operation and monitoring
- User access management
- Configurable digital and analog input/output
- USB communication port
- Optional RS232/RS485, Ethernet, 4G, GPS, remote monitoring software and mobile APP
Standard Features
- Perkins 4008-30TAG2 diesel engine
- High-efficiency brushless alternator
- Intelligent generator controller
- Radiator cooling system designed for high ambient temperature applications
- Output circuit breaker
- Maintenance-free starting battery
- Battery charger and battery switch
- Industrial exhaust silencer, exhaust bellows and elbows
- Heavy-duty steel base frame
- Anti-vibration shock absorbers
- Lifting and moving structure for installation and handling
- Oil and coolant discharge arrangement for maintenance
- Moving parts protection and hot parts protection
- Emergency stop system
- Toolbox and delivery documentation
Optional Configurations
- Silent canopy
- Fully weatherproof sound attenuated enclosure
- Containerized generator set
- External fuel tank
- Automatic fuel feeding system
- ATS automatic transfer switch
- Output cabinet, combining cabinet and distribution cabinet
- Synchronizing panel for parallel operation
- Remote control panel
- Remote monitoring software and mobile APP
- RS232/RS485 communication
- 4G, GPS and Ethernet communication card
- Additional digital and analog input/output modules
- Water jacket preheater
- Oil preheater
- Oil level maintainer
- Oil manual pump
- Heavy-duty air filtration system
- Residential silencer
- Remote radiator or heat exchanger
- PMG or AREP alternator excitation system
- Anti-condensation heater
- Winding and bearing RTD
- Double bearing alternator structure
- IP44 alternator protection class
- Ni-Cad batteries
- Load test cabinet
- Mobile trailer
- Customized voltage, canopy, fuel system and control system design
Applications
This Perkins powered diesel generator is suitable for heavy-duty industrial applications where stable, reliable and continuous power support is required. It can be used for industrial facilities, mining operations, oil and gas sites, data centers, hospitals, airports, commercial buildings, construction projects, emergency backup systems and independent power supply projects.
For mining sites and remote industrial facilities, this generator can support key loads such as pumps, ventilation systems, lighting, workshops, crushing equipment, communication systems and emergency backup loads. For commercial buildings, hospitals and data centers, it can be integrated with ATS systems and distribution cabinets to provide automatic standby power when the mains supply fails.
Enerzip Generator Solutions
As a professional Diesel Generator Manufacturer, enerzip provides open type diesel generators, silent diesel generators, containerized diesel generators, ATS systems, paralleling systems, high-voltage generator solutions and customized industrial power systems.
Enerzip can configure generator sets according to different project requirements, including engine brand, alternator brand, controller brand, voltage, frequency, canopy type, fuel tank capacity, noise level, ambient temperature, altitude, load type and installation environment.
Quality and Compliance
Enerzip generator systems can be configured according to applicable international electrical standards and customer site requirements. ISO 9001, ISO 14001, ISO 45001 and CE certificates are available for applicable product and project documentation. Factory testing, load testing and inspection can be arranged according to order requirements before delivery.
Price
Negotiable / Based on Configuration
The final price depends on engine configuration, alternator brand, controller brand, canopy type, voltage, fuel tank capacity, ATS system, paralleling system, transportation method and project requirements. Please contact Enerzip for the latest factory quotation.