1 CHINA EXPECTS FM WANG YI’S VISIT TO STEADILY ADVANCE CHINA-MONGOLIA COMPREHENSIVE STRATEGIC PARTNERSHIP: FM SPOKESPERSON WWW.GLOBALTIMES.CN PUBLISHED:2026/06/12      2 THE UNITED STATES EXTENDS CHILD PROTECTION COMPACT PARTNERSHIP WITH MONGOLIA THROUGH 2028 WWW.MN.USEMBASSY.GOV PUBLISHED:2026/06/12      3 MONGOLIA AND TURKEY EXCHANGED VIEWS ON EXPANDING BILATERAL RELATIONS WWW.OPEN.KG PUBLISHED:2026/06/12      4 MONGOLIA: STRENGTHENING AGRICULTURE THROUGH SUSTAINABLE FINANCE WWW.HORTIDAILY.COM PUBLISHED:2026/06/12      5 ULAANBAATAR HOSTS 15TH ASIAN TOURISM FORUM WWW.MONTSAME.MN PUBLISHED:2026/06/12      6 IN WASHINGTON, DC, MONGOLIA AND IUCN ELEVATE OPPORTUNITIES TO SUPPORT LAND RESTORATION, RANGELAND STEWARDSHIP AHEAD OF UNCCD COP17 WWW.IUCN.ORG PUBLISHED:2026/06/12      7 SMUGGLED DINOSAUR FOSSILS RETURN TO MONGOLIA AFTER TWO DECADES WWW.AFP.COM PUBLISHED:2026/06/12      8 CAN NORTHEAST ASIA’S NEW GEOPOLITICAL REALITY CREATE OPPORTUNITIES FOR MONGOLIA? WWW.THEDIPLOMAT.COM PUBLISHED:2026/06/11      9 MONGOLIAN FARMERS ARE CONCERNED ABOUT THE PROSPECT OF GRAIN IMPORTS FROM THE EAEU WWW.LOGOS-PRES.MD PUBLISHED:2026/06/11      10 KT PARTNERS WITH MONGOLIA'S TDB AND WOORI BANK FOR FOREIGNER-FOCUSED TELECOM, FINANCE SERVICES WWW.EN.SEDAILY.COM PUBLISHED:2026/06/11      БНХАУ-ЫН ГАДААД ХЭРГИЙН САЙД ВАН И ЗУРГААДУГААР САРЫН 13-15-НЫ ХООРОНД МОНГОЛ УЛСАД АЙЛЧИЛНА WWW.CNBC.MN НИЙТЭЛСЭН:2026/06/12     АЛТНЫ ҮНЭ СҮҮЛИЙН ЗУРГААН САРЫН ДООД ТҮВШНЭЭСЭЭ ЭРГЭН ӨСЖЭЭ WWW.MONTSAME.MN НИЙТЭЛСЭН:2026/06/12     ДӨРВӨН УЛИРЛЫН ХҮЛЭМЖ БАЙГУУЛЖ, НАРИЙН НОГООНЫ ХЭРЭГЦЭЭГ ХАНГАХ ТӨСӨЛД ГАРЫН ҮСЭГ ЗУРЛАА WWW.GOGO.MN НИЙТЭЛСЭН:2026/06/12     ЗЭСИЙН ЭКСПОРТЫН ОРЛОГО $3.8 ТЭРБУМД ХҮРЧЭЭ WWW.CNBC.MN НИЙТЭЛСЭН:2026/06/12     АЗИЙН АЯЛАЛ ЖУУЛЧЛАЛЫН ФОРУМ ЭХЭЛЛЭЭ WWW.MONTSAME.MN НИЙТЭЛСЭН:2026/06/12     ДЭЛХИЙН АДУУНЫ ӨДӨРТ 56 ОРНЫ ЗОЧИД ОРОЛЦОНО WWW.EAGLE.MN НИЙТЭЛСЭН:2026/06/12     ТОМИЛОЛТ: ЗӨӨВЧ-ОВОО ТӨСЛИЙН БҮТЭЭН БАЙГУУЛАЛТ ЭХЭЛЖ, АНХНЫ ЦООНОГОО ӨРӨМДЛӨӨ WWW.ITOIM.MN НИЙТЭЛСЭН:2026/06/12     МОНГОЛБАНК ХИЛ ДАМНАСАН ТӨЛБӨРИЙН ДЭВШИЛТЭТ ШИЙДЭЛ "MBRIDGE" ТӨСЛИЙН УДИРДАХ ХОРООНД НЭГДЛЭЭ WWW.MONTSAME.MN НИЙТЭЛСЭН:2026/06/11     ХУУЛИЙН ТӨСӨЛ: НДШ ТӨЛӨЛТТЭЙ ХОЛБООТОЙ ТАВАН ШИНЭЧЛЭЛТЭЙ ТАНИЛЦ WWW.EGUUR.MN НИЙТЭЛСЭН:2026/06/11     ХУУЛЬ БУСААР ХИЛ ДАВУУЛСАН ҮЛЭГ ГҮРВЭЛИЙН ОЛДВОРЫГ БУЦААН АВЧИРЛАА WWW.EAGLE.MN НИЙТЭЛСЭН:2026/06/11    

Enerzip 2000 kW / 2500 kVA Diesel Generators Powered by MTU Engines

Price: Үнэ тохиролцоно / Тохиргооноос хамаарна

Enerzip 2000 kW / 2500 kVA Diesel Generators Powered by MTU Engines

Enerzip 2000 kW / 2500 kVA Diesel Generators Powered by MTU Engines are designed for heavy-duty industrial prime power, standby power and emergency backup power applications. This generator model is suitable for data centers, mining sites, oil and gas facilities, large factories, airports, hospitals, commercial complexes, industrial parks, infrastructure projects and critical facilities requiring high-capacity three-phase diesel power.

This Enerzip diesel generator is powered by an MTU 20V4000 series diesel engine and matched with a high-efficiency brushless alternator, intelligent generator controller, heavy-duty steel base frame, radiator cooling system, industrial exhaust silencer, starting battery system and standard generator protection devices. The generator can be supplied as an open type, silent type, containerized type or customized power system according to project requirements.

The generator set model is M2750E5. Its prime power is 2000 kW / 2500 kVA and its standby power is 2200 kW / 2750 kVA. It can operate as a single high-power diesel generator or be integrated with ATS panels, synchronizing panels, output cabinets, combining cabinets, distribution cabinets, external fuel systems, remote monitoring systems and high-voltage power systems for large-scale industrial and emergency power projects.

Power Rating and Operating Conditions

The prime power rating is suitable for variable load applications where the generator may operate for an unlimited number of annual operating hours within the required maintenance intervals, in accordance with ISO 8528-1. The standby power rating is intended for emergency power supply in variable load applications when the mains power supply fails. Overload is not allowed under standby power operation.

The nominal power rating is based on standard reference conditions, including 25°C air inlet temperature, 100 kPa barometric pressure, approximately 100 m above sea level and 30% relative humidity. For high ambient temperature, high altitude, dusty environments, heavy motor starting loads or special site conditions, Enerzip can help confirm the correct generator rating, cooling system, fuel system and control configuration according to the actual project requirements.

Main Generator Specifications

Generator Model M2750E5
Prime Power 2000 kW / 2500 kVA
Standby Power 2200 kW / 2750 kVA
Frequency 50 Hz
Phase 3 Phase
Power Factor 0.8
Rated Speed 1500 rpm
Standard Voltage 400/230V
Available Voltage 380/220V, 415/240V
Fuel Type Diesel
Alternator Type Brushless
Cooling System Water-cooled
Application Prime Power and Standby Power

General Installation Data

Type Open Type Silent Type
Dimension L x W x H TBA according to final configuration 12192 x 2438 x 2896 mm
Weight TBA according to final configuration 23500 kg
Fuel Tank Based on configuration 2000 L
Sound Pressure Level at 75% Load, 1 m Based on installation TBA according to canopy design
Sound Pressure Level at 75% Load, 7 m Based on installation TBA according to canopy design

Weights, dimensions, fuel tank capacity and sound data are based on standard generator configurations. Final data may vary according to engine version, alternator brand, canopy structure, fuel tank design, exhaust system, control system, ventilation layout, cable connection method and customized project requirements.

Engine and Performance Data

Engine Brand MTU
Engine Model Options 20V4000G23F / 20V4000G14F
Fuel Diesel
Aspiration Turbocharged and intercooled
Cooling Water-cooled
Governor ECU
Cylinder Arrangement 20V
Application Prime and standby power
Engine Speed 1500 rpm

Fuel Consumption Data

Fuel consumption may vary according to engine version, load factor, ambient temperature, altitude, fuel quality, cooling arrangement and actual site installation. The following data is arranged according to the MTU 20V4000 engine versions provided for this generator rating.

Engine Version 100% Standby Power 100% Prime Power 75% Prime Power 50% Prime Power
MTU 20V4000G14F 583.4 L/h 530.4 L/h 383.4 L/h 258.0 L/h
MTU 20V4000G23F 501.6 L/h 456.0 L/h 345.6 L/h 241.2 L/h

Engine Specifications

Engine Brand MTU
Engine Model 20V4000G23F / 20V4000G14F
Engine Type 4-stroke diesel engine
Displacement 95.4 L
No. of Cylinders / Arrangement 20V
Bore x Stroke 170 x 210 mm
Compression Ratio 16.4:1
Engine Speed 1500 rpm
Aspiration Turbocharged and intercooled
Cooling System Water-cooled
Speed Governor ECU

Exhaust System Data

Exhaust Stack Gas Temperature Max. 510°C
Exhaust Gas Flow Rate Max. 7.1–8.7 m³/s, depending on engine version
Maximum Allowable Exhaust Back Pressure 85 mbar
Exhaust System Industrial silencer, exhaust bellows and elbows according to installation design

Fuel System Data

Maximum Restriction at Lift Pump 11.0 bar
Maximum Fuel Flow 27 L/min
Standard Fuel Type Diesel
Optional Fuel System External fuel tank, automatic fuel feeding system, low fuel level alarm and fuel transfer system

Cooling System Data

Cooling Type Water-cooled
Radiator Air Flow TBA according to final radiator configuration
Total Oil Capacity 390 L
Total Coolant Capacity 750 L
Maximum Allowable Combustion Air Inlet Temperature 50°C
Cooling Configuration Standard radiator, remote radiator or heat exchanger according to project requirements

The cooling system can be configured for demanding site conditions. For high ambient temperature applications, Enerzip can design the generator cooling system for operation in 50°C / 122°F ambient conditions, subject to final site installation, ventilation layout and air flow requirements.

Electrical System Data

Starter Motor Rated Voltage DC24V
Start Battery 4 x 120Ah
Battery Charging Alternator DC24V, according to final configuration
Battery System Maintenance-free starting battery, battery charger and battery switch

Inlet Air System

Air Filter Dry type
Maximum Combustion Air Intake Restriction 50 mbar
Combustion Air Inlet Flow Rate 2.65–3.1 m³/s, depending on engine version
Maximum Allowable Combustion Air Inlet Temperature 50°C
Optional Air Intake Configuration Heavy-duty air filtration system for dusty or harsh site environments

Alternator Specifications

The generator is matched with a high-efficiency brushless alternator selected according to the required voltage, frequency, load type, motor starting requirement, installation environment and project configuration. Different alternator brands, excitation systems and protection classes can be supplied according to customer requirements.

Alternator Type Brushless
Excitation Type Self-excited
Insulation and Temperature Rise Class H/H
Number of Phase Three phase
Winding Leads 6
Winding Connection Standard Star
Winding Pitch Two thirds
No. of Bearings Single bearing
Coupling System Flexible disc coupling
Maximum Overspeed 2250 rpm
Coating Type Vacuum impregnation
IP Rating IP23

Control System

The Enerzip 2000 kW / 2500 kVA diesel generator can be equipped with an intelligent generator controller for prime power, standby power and automatic mains failure applications. The controller supports generator monitoring, engine protection, alternator protection, operating history management, maintenance warning and optional remote monitoring.

  • Single generator set controller for prime or standby operation
  • Manual start and remote start operation
  • MRS application for manual and remote start scenarios
  • AMF application for automatic mains failure operation
  • Generator power, frequency, power factor, voltage and current detection
  • Engine protection, alternator protection and generator protection
  • Emergency stop function
  • Event log, running hours history and maintenance warning
  • LCD screen for operation and monitoring
  • User access management
  • Input and output configuration
  • USB communication port
  • Optional remote control and cloud service functions

Standard Features

  • MTU 20V4000 series diesel engine
  • Radiator cooling system designed for high ambient temperature applications
  • High-efficiency brushless alternator
  • Intelligent generator controller
  • Output circuit breaker
  • Maintenance-free starting battery
  • Battery charger and battery switch
  • Steel industrial exhaust silencer
  • Exhaust bellows and elbows
  • Heavy-duty steel chassis
  • Anti-vibration shock absorbers
  • Lifting and moving structure for installation and handling
  • Oil and coolant discharge arrangement for maintenance
  • Moving parts protection
  • Hot parts protection
  • Special toolbox
  • Delivery documentation
  • Manual and auto-start control panel
  • DC and AC wiring harnesses

Sound Attenuated Enclosure

The generator can be supplied with a fully weatherproof sound attenuated enclosure for outdoor installation. The silent enclosure is designed with internal exhaust silencer, ventilation arrangement, maintenance access doors and corrosion-resistant construction. Silent canopy design can be customized according to required noise level, ambient temperature, installation space, maintenance access and site operating conditions.

Optional Engine Features

  • Water jacket preheater
  • Oil preheater
  • Oil level maintainer
  • Oil manual pump
  • Heavy-duty air filtration system
  • Residential silencer
  • Remote radiator
  • Heat exchanger
  • Customized cooling system for high ambient temperature sites

Optional Alternator Features

  • PMG excitation system
  • AREP excitation system
  • Anti-condensation heater
  • Winding RTD
  • Bearing RTD
  • Double bearing structure
  • IP44 protection class
  • Anti-damp and anti-corrosion treatment
  • Alternator preheater

Optional Control System Features

  • Synchronizing panel
  • Remote control panel
  • RS232 / RS485 communication
  • 4G wireless communication
  • GPS wireless communication
  • Ethernet communication card
  • Additional digital input and output modules
  • Additional analog input and output modules
  • Remote monitoring software
  • Mobile APP monitoring
  • Ni-Cad batteries

Optional Generating Set Features

  • External fuel tank
  • Automatic fuel feeding system
  • ATS automatic transfer switch
  • Output cabinet
  • Combining cabinet
  • Distribution cabinet
  • Load test cabinet
  • Mobile trailer
  • Containerized generator set
  • Silent canopy
  • Customized voltage and control system design
  • High-voltage generator system configuration

Design Criteria

The generator set can be configured to meet applicable diesel generator performance requirements for transient response, emergency standby operation and industrial power supply applications. The generator system can be designed according to project requirements for motor starting capability, load step performance, voltage recovery, frequency stability, cooling performance, ventilation arrangement and site installation conditions.

The cooling system can be designed for operation in high ambient temperature environments, including 50°C / 122°F ambient conditions, subject to final site installation and ventilation design. For large industrial power systems, Enerzip can provide ATS systems, synchronization systems, paralleling panels, distribution cabinets and high-voltage solutions according to electrical design requirements.

Applications

This MTU powered diesel generator is suitable for heavy-duty industrial and critical power applications requiring stable, rugged and reliable power output. It can be used for data centers, mining operations, oil and gas facilities, large factories, hospitals, airports, industrial parks, commercial buildings, infrastructure projects, manufacturing plants, emergency backup systems and remote power supply projects.

For data centers and critical facilities, this generator can be integrated with ATS systems, synchronization panels, fuel systems and distribution cabinets to provide reliable standby power when the mains supply fails. For mining, oil and gas, and heavy industrial sites, it can support pumps, ventilation systems, compressors, workshops, crushing equipment, conveyor systems, lighting systems, communication systems and other key loads.

For larger power systems, multiple generator sets can be connected through synchronization panels and power distribution systems. Enerzip can support project configuration according to load capacity, voltage level, cable connection, fuel supply, control logic, enclosure type, ambient temperature, altitude and installation requirements.

Enerzip Generator Solutions

For more details about this product series, please visit 2000 kW / 2500 kVA Diesel Generators.

As an industrial generator manufacturer and power system supplier, enerzip provides open type diesel generators, silent diesel generators, containerized diesel generators, ATS systems, paralleling systems, high-voltage generator solutions and customized industrial power systems for different project applications.

Enerzip can configure generator sets according to engine brand, alternator brand, controller brand, voltage, frequency, canopy type, container structure, fuel tank capacity, noise level, ambient temperature, altitude, load type, installation environment and project requirements.

Quality and Compliance

Enerzip generator systems can be configured according to applicable international electrical standards and customer site requirements. ISO 9001, ISO 14001, ISO 45001 and CE certificates are available for applicable product and project documentation. Factory testing, load testing and inspection can be arranged before delivery according to order requirements.

The generator system can be configured with reference to applicable standards and project requirements, including machinery safety, low-voltage electrical safety, generator set safety, transient response performance and emergency standby power system requirements. Final technical data, dimensions, weights and configuration may be adjusted according to actual production design, component selection and customer requirements.

Price

Negotiable / Based on Configuration

The final price depends on engine configuration, alternator brand, controller brand, canopy type, container type, voltage, fuel tank capacity, ATS system, paralleling system, high-voltage configuration, transportation method and project requirements. Please contact Enerzip for the latest factory quotation.