Enerzip 520 kW / 650 kVA Diesel Generators Powered by Volvo Penta Engines
| Price: | Үнэ тохиролцоно / Тохиргооноос хамаарна |
Enerzip 520 kW / 650 kVA Diesel Generators Powered by Volvo Penta Engines
Enerzip 520 kW / 650 kVA Diesel Generators Powered by Volvo Penta Engines are designed for industrial prime power, standby power and emergency backup power applications. This generator model is suitable for factories, commercial buildings, hospitals, data centers, telecom facilities, construction projects, mining support facilities, water pump stations, farms, industrial workshops and other sites requiring stable three-phase diesel power.
This Enerzip diesel generator is powered by a Volvo Penta TWD1644GE diesel engine and matched with a high-efficiency brushless alternator, digital generator control system, heavy-duty steel base frame, radiator cooling system, industrial exhaust silencer and standard generator protection devices. The generator can be supplied as an open type, silent type, trailer type, containerized type or customized power system according to project requirements.
The generator set model is V715E5. Its prime power is 520 kW / 650 kVA and its standby power is 572 kW / 715 kVA. It can operate as a single diesel generator or be integrated with ATS panels, synchronizing control panels, output breakers, distribution boards, remote monitoring systems and external fuel systems for industrial power supply and standby power projects.
Power Rating and Application Definition
The prime power rating is suitable for variable load applications where the generator may operate for an unlimited number of annual operating hours within the required maintenance intervals, according to ISO 8528-1. The permissible average power output during a 24-hour period should not exceed the recommended average loading condition according to project design and applicable generator standards.
The standby power rating is intended for emergency power supply under agreed operating conditions when the mains power supply fails. Standby power is suitable for variable load emergency applications, and no overload capability is available under standby rating. For continuous operation, high-load applications, high ambient temperature sites, high altitude conditions or special installation requirements, Enerzip can help confirm the correct generator rating, cooling system, fuel tank capacity and control configuration according to the actual load profile.
Main Generator Specifications
| Generator Model | V715E5 |
| Prime Power | 520 kW / 650 kVA |
| Standby Power | 572 kW / 715 kVA |
| Frequency | 50 Hz |
| Phase | 3 Phase |
| Power Factor | 0.8 |
| Rated Speed | 1500 rpm |
| Standard Voltage | 400/230V |
| Available Voltage | 380/220V, 415/240V |
| Fuel Type | Diesel |
| Alternator Type | Brushless |
| Cooling System | Water-cooled |
| Control System | Digital generator control system |
| Application | Prime Power and Standby Power |
Voltage and Current Data
| Voltage | Standby Power | Prime Power | Standby Current |
| 415/240V | 715 kVA / 572 kW | 650 kVA / 520 kW | 994.7 A |
| 400/230V | 715 kVA / 572 kW | 650 kVA / 520 kW | 1032.0 A |
| 380/220V | 715 kVA / 571 kW | 650 kVA / 520 kW | 1086.4 A |
Performance Data
| Engine Brand | Volvo Penta |
| Engine Model | TWD1644GE |
| Speed Control Type | ECM |
| Phase | 3 Phase |
| Control System | Digital |
| Starter Motor Voltage | 24V |
| Frequency | 50 Hz |
| Engine Speed | 1500 rpm |
Fuel Consumption Data
| Load Condition | Fuel Consumption |
| 100% Standby Power | 194 g/kWh |
| 100% Prime Power | 193 g/kWh |
| 75% Prime Power | 195 g/kWh |
| 50% Prime Power | 195 g/kWh |
Fuel consumption data is based on standard reference conditions with diesel fuel. Actual fuel consumption may vary according to site altitude, ambient temperature, load factor, fuel quality, cooling arrangement, generator configuration and installation conditions.
Dimension and Weight
| Dimension | Open Type | Silent Type |
| Length | 3055 mm | 4912 mm |
| Width | 1380 mm | 1600 mm |
| Height | 2220 mm | 2465 mm |
| Net Weight | 4325 kg | Based on final silent canopy configuration |
| Fuel Tank | 1000 L | Based on final silent canopy configuration |
Dimensions, weights and fuel tank capacity are based on standard generator configurations. Final data may vary according to alternator brand, canopy structure, fuel tank design, exhaust system, control system, cable connection method and customized project requirements.
Engine Specifications
| Engine Brand | Volvo Penta |
| Engine Model | TWD1644GE |
| No. of Cylinders | 6 |
| Cylinder Arrangement | In-line |
| Cycle | 4 Stroke |
| Displacement | 16 L |
| Bore | 144 mm |
| Stroke | 165 mm |
| Compression Ratio | 16.8:1 |
| Wet Weight, Engine Only | 1810 kg |
| Wet Weight, Genpac | 2767 kg |
Cooling System
| Heat Rejection Radiation from Engine at Standby Power | 24 kW |
| Heat Rejection Radiation from Engine at Prime Power | 21 kW |
| Heat Rejection to Coolant at Standby Power | 228 kW |
| Heat Rejection to Coolant at Prime Power | 211 kW |
| Fan Power Consumption | 21 kW |
| Fan Drive Ratio | 1.04:1 |
| Coolant Capacity, Engine | 25 L |
| Coolant Capacity, Standard Radiator | 50 L |
| Coolant Pump Drive Ratio | 1.85:1 |
| Minimum Coolant Flow | 4.8 L/s |
| Thermostat Start to Open | 82°C |
| Thermostat Fully Open | 92°C |
| Maximum Static Pressure Head | 100 kPa |
| Minimum Static Pressure Head | 70 kPa |
| Standard Pressure Cap Setting | 75 kPa |
| Maximum Top Tank Temperature | 107°C |
The cooling system can be configured for demanding site conditions. For high ambient temperature applications, the generator cooling system can be designed for operation in 50°C / 122°F ambient conditions, subject to final installation design, ventilation arrangement and air flow requirements.
Inlet and Exhaust Data
| Maximum Intake Restriction | 3 kPa |
| Reference Data at Standby Power | 432 kW |
| Reference Data at Prime Power | 406 kW |
| Exhaust Gas Temperature after Turbine at Standby Power | 480°C |
| Exhaust Gas Temperature after Turbine at Prime Power | 485°C |
| Maximum Back Pressure in Exhaust Line | 10 kPa |
| Exhaust Gas Flow at Standby Power | 100 m³/min |
| Exhaust Gas Flow at Prime Power | 93.5 m³/min |
Fuel System
| System Supply Flow | 170 L/h |
| Maximum Restriction of Fuel Supply Line | 10 kPa |
| Maximum Pressure of Fuel Supply Line | 0 kPa |
| System Return Flow | 25 L/h |
| Maximum Restriction of Fuel Return Line | 20 kPa |
| Maximum Allowable Inlet Fuel Temperature | 60°C |
Lubrication System
| Oil Consumption at Standby Power | 0.11 L/h |
| Oil Consumption at Prime Power | 0.10 L/h |
| Oil System Capacity Including Filters | 48 L |
| Oil Sump Capacity, Maximum | 42 L |
| Oil Sump Capacity, Minimum | 32 L |
| Oil Change Interval | 500 hours |
| Oil Pressure at Rated Speed | 300–500 kPa |
| Engine Angularity Limits | 30° |
Electrical System
| Voltage | 24V |
| Alternator Output | 80 A |
| Starter Motor | 7 kW |
Alternator Specifications
The generator is matched with a high-efficiency brushless alternator selected according to the required voltage, frequency, site load condition, motor starting requirement and project configuration. Different alternator brands and excitation systems can be supplied according to customer requirements.
| Number of Phase | 3 Phase |
| Power Factor | 0.8 |
| Poles | 4 |
| Winding Connection | Star-series |
| Terminals | 12 |
| Insulation Type | Class H |
| Winding Pitch | 2/3 |
| IP Rating | IP23 |
| Excitation System | Self-excited |
| Bearing | Single bearing |
| Coating | Vacuum impregnation |
| Voltage Regulator | AVR |
| Coupling | Flexible disc coupling |
Control Panel Configuration
The Enerzip control panel is designed for generator monitoring, engine protection, alternator protection, AMF operation and optional remote monitoring. The system can be configured according to manual start, automatic start, standby power, prime power, ATS connection or synchronization operation.
- Emergency stop button
- Protection MCB
- Battery charger
- Integrated aviation plug
- ATS connection
- Digital control module
- Manual start and automatic start/stop operation
- 3-phase generator set monitoring
- Support for engines equipped with electronic control unit
- Comprehensive diagnostic message display
- Push buttons for simple operation and lamp test
- Graphic back-lit LCD display
- Adjustable parameters via keyboard or PC
- Mains measurements for 50Hz and 60Hz applications
- Generator measurements for 50Hz and 60Hz applications
- Comprehensive shutdown and warning functions under fault conditions
Generator Protection Functions
- Over-voltage protection
- Under-voltage protection
- Over-frequency protection
- Under-frequency protection
- Current asymmetry protection
- Voltage asymmetry protection
- Over-current protection
- Overload protection
- Battery voltage monitoring
- Engine speed measurement by magnetic pick-up
- Configurable analog inputs
- Configurable programmable binary inputs and outputs
- Warm-up function
- Cooling-down function
- Generator circuit breaker and mains circuit breaker control with feedback
- RS232 interface
- Modem communication support
- Running hours counter
- IP65 sealed control panel option
- Event log
Control Panel Benefits
- Less wiring and fewer external components
- Integrated generator control solution
- Reduced engineering and programming workload
- User-friendly setup and button layout
- Module can be configured for different applications
- PC software support for simplified configuration
- Wide range of communication capabilities
- Suitable for prime power, standby power and AMF applications
Control System Operating Conditions
| Operation Temperature | -20°C to +70°C |
| Storage Temperature | -30°C to +80°C |
| Operating Humidity | 95% without condensation |
| Vibration | 5–100Hz, a=4g; 5–25Hz, ±1.6 mm |
| Shock | a = 500 m/s² |
Standard Features
- Volvo Penta TWD1644GE diesel engine
- High-efficiency brushless alternator
- Digital generator control module
- Manual and auto-start control panel
- DC and AC wiring harnesses
- Radiator cooling system
- Heavy-duty steel base frame
- Industrial exhaust silencer
- Output circuit breaker
- Emergency stop system
- Generator protection functions
- Engine protection functions
- Alternator protection functions
- Battery charging system
- Anti-vibration mounting system
- Operation and maintenance documentation
Sound Attenuated Enclosure
The generator can be supplied with a fully weatherproof sound attenuated enclosure for outdoor installation. The enclosure is designed with internal exhaust silencer, ventilation arrangement, maintenance access doors and corrosion-resistant construction. Silent canopy design can be customized according to noise level requirements, ambient temperature, installation space and site operating conditions.
Optional Configurations
| Engine Options | Water jacket pre-heater, fuel heater |
| Alternator Options | Winding temperature measuring instrument, alternator pre-heater, PMG, anti-damp and anti-corrosion treatment, anti-condensation heater, winding and bearing RTD |
| Generator Set Options | Tools with the machine, extended range fuel tank, bunded fuel tank, rental type canopy, trailer |
| Fuel System Options | Low fuel level alarm, automatic fuel feeding system, fuel T-valves, fuel transfer system control |
| Lubrication System Options | Oil pre-heater, oil temperature sensor |
| Cooling System Options | Front heat protection, customized cooling arrangement |
| Control Panel Options | Remote control panel, ATS, synchronizing controller, adjustable earth leakage relay, Ethernet interface, GSM modem, wireless internet, RS232-RS485 dual port interface |
Additional Control Options
- Synchronizing control panel
- Distribution board with sockets kit and power busbar
- Battery trickle charge ammeter
- Earth leakage protection
- Earth fault protection
- Low fuel level alarm
- Low fuel level shutdown
- High fuel level alarm
- Fuel transfer system control
- Low coolant level shutdown
- High lubricating oil temperature shutdown
- Overload alarm through breaker alarm switch
- Engine coolant heater controls
- Control panel heater
- Speed adjust switch
- Oil temperature display on LCD screen
- Additional 8 inputs and outputs
- Remote monitoring and remote control through Ethernet or wireless communication
Design Criteria
The generator set can be configured to meet applicable diesel generator performance requirements for transient response, emergency standby operation and industrial power supply applications. The cooling system can be designed for operation in high ambient temperature environments, including 50°C / 122°F conditions, subject to final site installation and ventilation design.
For motor starting applications, the alternator and generator output can be selected according to the starting current, load step, voltage dip requirement and site operating mode. For critical power applications, Enerzip can provide ATS systems, synchronization systems, paralleling panels and distribution solutions according to the electrical design.
Applications
This Volvo Penta powered diesel generator is suitable for industrial and commercial applications requiring reliable performance, fast response and stable power output. It can be used in factories, commercial buildings, hospitals, data centers, construction sites, farms, water pump stations, telecom projects, workshops, warehouses, emergency backup systems and remote power supply applications.
For industrial sites, this generator can support pumps, lighting systems, production equipment, ventilation systems, maintenance workshops, control rooms and emergency backup loads. For commercial buildings, hospitals and public facilities, it can be integrated with ATS panels and distribution cabinets to provide automatic standby power when the mains supply fails.
For customized power systems, Enerzip can support project configuration according to load capacity, voltage level, cable connection, fuel supply, control logic, enclosure type and site installation requirements.
Enerzip Generator Solutions
As a professional 520 kW / 650 kVA Diesel Generator Manufacturer & Supplier, enerzip provides open type diesel generators, silent diesel generators, trailer generators, containerized diesel generators, ATS systems, paralleling systems, high-voltage generator solutions and customized industrial power systems for different project applications.
Enerzip can configure generator sets according to engine brand, alternator brand, controller brand, voltage, frequency, canopy type, fuel tank capacity, noise level, ambient temperature, altitude, load type, installation environment and project requirements.
Quality and Compliance
Enerzip generator systems can be configured according to applicable international electrical standards and customer site requirements. ISO 9001, ISO 14001, ISO 45001 and CE certificates are available for applicable product and project documentation. Factory testing, load testing and inspection can be arranged before delivery according to order requirements.
The generator set can be configured with reference to applicable standards and project requirements, including diesel generator performance requirements, transient response requirements, machinery safety, low-voltage electrical safety and emergency standby power system requirements. Final generator configuration, technical data and dimensions may be adjusted according to actual production design, component selection and customer requirements.
Price
Negotiable / Based on Configuration
The final price depends on engine configuration, alternator brand, controller brand, canopy type, voltage, fuel tank capacity, ATS system, paralleling system, transportation method and project requirements. Please contact Enerzip for the latest factory quotation.