Enerzip 1000 kW / 1250 kVA Diesel Generators Powered by Yuchai Engines
| Price: | Үнэ тохиролцоно / Тохиргооноос хамаарна |
Enerzip 1000 kW / 1250 kVA Diesel Generators Powered by Yuchai Engines are designed for industrial prime power, standby power and emergency backup power applications. This generator model is suitable for manufacturing plants, commercial buildings, public facilities, infrastructure projects, municipal engineering, construction sites, remote areas, independent microgrids and other applications requiring stable three-phase diesel power.
This Enerzip diesel generator is powered by a Yuchai YC6C1660-D31 diesel engine and matched with a high-efficiency brushless alternator, standard generator control panel, main line circuit breaker, radiator cooling system, industrial muffler, anti-vibration absorber and complete generator protection devices. The generator can be supplied as an open type, rainproof type, soundproof type, trailer type or customized power system according to project requirements.
The generator set model is DB-1000GF. It is rated at 1000 kW / 1250 kVA, with 50 Hz frequency, 1500 rpm rated speed, 400/230V standard voltage and 0.8 lagging power factor. It can be used as a primary power source or backup power source for industrial, commercial, infrastructure and remote power supply applications.
Generator Set Data
| Genset Model | DB-1000GF |
| Rated Power | 1000 kW / 1250 kVA |
| Rated Current | 1800 A |
| Rated Frequency | 50 Hz |
| Power Factor | 0.8 lagging |
| Rated Voltage | 400/230V |
| Voltage Option | Customizable according to project requirements |
| Fuel Type | Diesel |
| Application | Prime Power and Standby Power |
Standard Features
- Yuchai YC6C1660-D31 diesel engine
- Radiator suitable for up to 50°C ambient temperature
- Belt-driven fan with safety guard
- 24V charging alternator
- Dry type air filter
- Fuel filter and oil filter
- Single bearing alternator
- IP23 protection level
- Class H/H insulation system
- Main line circuit breaker
- Standard generator control panel
- Anti-vibration absorber
- Industrial muffler
- User manual and standard documentation
Diesel Engine Data
| Engine Manufacturer | Yuchai |
| Engine Model | YC6C1660-D31 |
| Prime Power | 1110 kW |
| Standby Power | 1221 kW |
| Rated Speed | 1500 r/min |
| Cycle | 4 stroke |
| Cylinder Arrangement | 6 cylinders, vertical in-line |
| Aspiration | Turbocharged and intercooled |
| Displacement | 39.58 L |
| Bore x Stroke | 200 x 210 mm |
| Compression Ratio | 13.5:1 |
| Governor Type | ECU |
| Start Battery Voltage | 24V DC |
Fuel System
| Fuel Supply System | Common rail |
| Fuel Type | Diesel |
| Fuel Consumption at 100% Prime Power | 276.8 L/h |
| Fuel Consumption at 50% Prime Power | 156.9 L/h |
| Optional Fuel System | Daily fuel tank, fuel level sensor, water separator and automatic fuel feeding system |
Fuel consumption data is based on standard operating conditions. Actual fuel consumption may vary according to load factor, ambient temperature, altitude, fuel quality, cooling arrangement, generator configuration and site installation conditions.
Oil System
| Engine Oil Capacity | 130 L – 160 L |
| Optional Oil System | Oil heater and related monitoring accessories according to project requirements |
Cooling System
| Cooling Way | Water-cooled |
| Radiator Design | Suitable for up to 50°C ambient temperature |
| Fan Drive | Belt-driven fan with safety guard |
| Cooling Configuration | Standard radiator or customized cooling arrangement according to site requirements |
The cooling system can be configured for demanding site conditions. For high ambient temperature applications, Enerzip can design the generator cooling system for operation in 50°C ambient conditions, subject to final installation design, ventilation arrangement and air flow requirements.
Alternator Data
The generator can be matched with alternator brands such as LEROY SOMER, STAMFORD, SIEMENS, MARATHON, ENGGA or Shanghai Stamford according to project requirements. The alternator is selected according to voltage, frequency, motor starting requirement, load type and site operating conditions.
| Alternator Brand Options | LEROY SOMER / STAMFORD / SIEMENS / MARATHON / ENGGA / Shanghai Stamford |
| Excitation Mode | Brushless and self-exciting |
| Phase and Wiring | 3-phase 4-wire |
| Connection Type | Y type connection |
| Alternator Capacity | 1000 kW / 1250 kVA |
| Alternator Efficiency | 95% |
| Overload Capacity | 110% PRP load can run for 1 hour |
| Protection Level | IP22–IP23 |
| Insulation Class / Temperature Rise | H/H |
| Telephone Influence Factor | < 50 |
| THF | < 2% |
| Steady State Voltage Regulation | ≤ ±1% |
| Altitude | ≤ 1000 m |
Genset Electrical Performance
| Voltage Regulation | ≥ ±5% |
| Voltage Regulation, Steady State | ≤ ±1% |
| Sudden Voltage Warp, 100% Sudden Reduce | ≤ +25% |
| Sudden Voltage Warp, Sudden Increase | ≤ -20% |
| Voltage Stable Time, 100% Sudden Reduce | ≤ 6 s |
| Voltage Stable Time, Sudden Increase | ≤ 6 s |
| Frequency Regulation, Steady State | ≤ 5% |
| Frequency Waving | ≤ 1.5% |
| Sudden Frequency Warp, 100% Sudden Reduce | ≤ +12% |
| Sudden Frequency Warp, Sudden Increase | ≤ -10% |
| Frequency Recovery Time, 100% Sudden Reduce | ≤ 5 s |
| Frequency Recovery Time, Sudden Increase | ≤ 5 s |
Dimension and Weight
| Generator Type | Overall Size | Weight |
| Open Type | 5400 x 2350 x 2700 mm | 16200 kg |
Dimensions and weight are based on standard generator configurations. Final dimensions may vary according to alternator brand, canopy design, fuel tank capacity, exhaust system, control panel, cable connection method and customized project requirements.
Engine Options
- 2 kW heater
- 4 kW heater
- Water separator
- Daily fuel tank
- Fuel level sensor
- Additional engine protection devices according to site requirements
Alternator Options
- Anti-condensation heater
- Permanent magnet generator, PMG
- Drop CT for paralleling operation
- Alternative alternator brands according to project requirements
- Special alternator protection configuration for harsh environments
Control System Options
- Remote control panel
- Auto Transfer Switch, ATS
- Paralleling system
- Generator monitoring system
- Customized control logic according to project requirements
Generator Set Options
- Rainproof type
- Soundproof type
- Trailer type
- Open type
- Customized fuel tank
- Distribution cabinet
- External fuel system
- Load bank test support
- Special enclosure design for outdoor installation
- Customized industrial power system
Design and Application
This Yuchai powered diesel generator is suitable for applications requiring high-capacity power, strong starting performance and stable operation. It can be used as a primary power source or backup power source for industrial and manufacturing facilities, commercial and public buildings, infrastructure projects, municipal engineering, special events, remote areas and independent microgrids.
For industrial and manufacturing sites, the generator can support production lines, pumps, compressors, ventilation systems, lighting systems, control systems and emergency loads. For commercial buildings and public facilities, it can be integrated with ATS systems to provide automatic power transfer when mains power fails. For infrastructure and municipal engineering projects, the generator can provide reliable power for temporary construction, emergency support and remote operating locations.
For independent microgrids and remote areas, this generator can be configured with external fuel systems, distribution cabinets, synchronization systems and monitoring devices according to project requirements. Enerzip can support project configuration according to load capacity, voltage level, cable connection, fuel supply, control logic, enclosure type and site installation requirements.
Enerzip Generator Solutions
As a professional Diesel Generator Manufacturer, enerzip provides open type diesel generators, silent diesel generators, trailer generators, containerized diesel generators, ATS systems, paralleling systems, high-voltage generator solutions and customized industrial power systems for different project applications.
Enerzip can configure generator sets according to engine brand, alternator brand, controller brand, voltage, frequency, canopy type, fuel tank capacity, noise level, ambient temperature, altitude, load type, installation environment and project requirements.
Quality and Compliance
Enerzip generator systems can be configured according to applicable international electrical standards and customer site requirements. ISO 9001, ISO 14001, ISO 45001 and CE certificates are available for applicable product and project documentation. Factory testing, load testing and inspection can be arranged before delivery according to order requirements.
Generator configuration, technical data and final dimensions may be adjusted according to actual production design, component selection and customer requirements. Enerzip can provide technical support for generator selection, load calculation, ATS configuration, paralleling system design, high-power generator system design and site installation requirements.
Price
Negotiable / Based on Configuration
The final price depends on engine configuration, alternator brand, controller brand, canopy type, voltage, fuel tank capacity, ATS system, paralleling system, transportation method and project requirements. Please contact Enerzip for the latest factory quotation.